Logged in as

Customer Service

Available jobs

Job opportunities at Elvaco

Elvaco is a growing company with talented, down-to-earth people who want to deliver that little extra while at the same time having fun!

 

Apply now!

CMi1020w

Meter Connectivity Modules

Elvaco offers meter connectivity modules for heat and electricity meters. These are used with a specific type of meter to collect data and deliver strucutred meter data reports to a receiving system, or to enable a meter to communicate by M-Bus/Wireless M-Bus.

CMi1020w - Integrated MCM for Landis+Gyr E350

CMi1020w is an integrated meter connectivity module which is mounted in a Landis+Gyr E350 electricity meter to collect meter data and deliver it to a receiving system by Wireless M-Bus. The product can be ordered with a default or customized configuration. This makes CMi1020w a perfect option when a high degree of flexibility and an attractive price point is required and wiring is not an option, for example in sub-metering projects.
  • Total: 2
  • Total: 2

Mechanics

Casing material:
Polycarbonate
Dimensions (w x h x d):
166 x 92 x 35 mm
Protection class:
IP20
Weight:
125 g
Mounting:
In Landis+Gyr E350

Electrical connections

Supply voltage:
From L+G E350
Rate inputs:
Screw terminal. Cable 0.25-1.5 mm², 0.5 Nm tightening torque

Electrical characteristics

Nominal voltage:
220-240 VAC (+/-10%)
Frequency:
50/60 Hz
Power consumption (max):
<0.5 W
Installation category:
CAT 4
Rate input low voltage:
<10 VAC
Rate input high voltage:
>24 VAC
Rate input max voltage:
230 VAC
Rate input minimum detection time:
1 s

Environmental specifications

Operating temperature:
-40 °C to 70 °C
Operating humidity:
5 % to 90 %, non-condensing
Operating altitude:
0-2000 m
Pollution degree:
Degree 2
Usage environment:
Indoors
Storage temperature:
-40 °C to +70 °C

Temperature sensor, margin of error

Humidity sensor, margin of error

User interface

Green LED:
Power
Red LED:
Error

M-Bus

Interfaces:
M-Bus slave
M-Bus standard:
EN 13757-4. Communication by T1 (default) or C1

Wireless M-Bus

Integrated M-Bus Master

Wireless M-Bus Receiver

M-Bus slave interface

Frequency, Wireless M-Bus:
868.95 MHz
Addressing modes:
Electricity meter's secondary address
M-Bus information:
Default or custom configuration
Transmit power:
25 mW
Transmit interval:
16 to 510 seconds (default: 16 seconds)
Encryption:
Unencrypted (default) or encrypted

General

Data storage (examples)

Mobile Network

Fixed Network (Ethernet)

Integration

Meter implementation:
Landis+Gyr E350
Number of connected meters:
1

Approvals

EMC:
EN 301489-1, EN 301489-3
Safety:
EN 61010-1, CAT 4

Connections and Interfaces

Transmissions