Logged in as

CMi2110 - Integrated MCM for Landis+Gyr UH50

CMi2110 is a powerful and ersatile meter connectiity module which is mounted inside a Landis+Gyr UH50 heat meter to act as a Gateway for the mobile network. The module is easily installed through text messages, and is thereafter ready to read the meter and delier customized meter data reports to a receiing system by a selected time schedule and integration protocol ia the mobile network.
  • Total: 6
  • Total: 6

Mechanics

Dimensions (w x h x d):
85 x 38 x 25 mm
Protection class:
IP54
Weight:
30 g
Mounting:
In Landis+Gyr UH50/UC50

Electrical connections

Supply voltage:
WZU-AC 110/230-50 or WZU-ACDC24-50
M-Bus master port:
Push-pull connector, cable area 0.2-0.75 mm²
USB slave port:
Type micro B
Network:
Mobile (Radio)

Electrical characteristics

Nominal voltage WZU-AC 110/230-50 power supply:
110-240 VAC (±10%)
Nominal voltage WZU-ACDC24-50 power supply:
12-48 VDC
Frequency:
50/60 Hz
Power consumption (max):
<6 W
Power consumption (nom):
<1 W
Installation category:
CAT 2

Environmental specifications

Operating temperature:
-20 °C to +55 °C
Operating humidity:
5 % to 90 %, non-condensing
Operating altitude:
0-2000 m
Pollution degree:
Degree 2
Usage environment:
Indoors
Storage temperature:
-40 °C to +85 °C

Temperature sensor, margin of error

Humidity sensor, margin of error

User interface

Green LED:
Power
Red LED:
Error
Yellow LED:
GSM status
Blue LED:
USB active
Push button:
Factory reset
Configuration:
SMS, HTTP, GSM CSD, Telnet

M-Bus

Interfaces:
Integrated M-Bus Master
M-Bus standard:
EN 13757
Transparent M-Bus:
GSM and TCP/IP (software limit does not apply to transparent M-Bus mode)
Decryption:
No

Wireless M-Bus

Integrated M-Bus Master

M-Bus baud rate, master port:
2400 and 9600 bit/s
Maximum number of M-Bus devices (software limit):
128
M-Bus search modes:
Primary, secondary
Maximum cable length:
1000 m (100 nF/km, maximum 90 ohm)

Wireless M-Bus Receiver

M-Bus slave interface

General

Real-time clock backup:
12 h
Real-time clock accuracy:
<2 s/day
Script engine:
Intelligent script engine for active content generation
Software/firmware update:
GSM/GPRS/HTTP
Metering reports:
HTTP, FTP, SMTP (e-mail)

Data storage (examples)

1 meter:
500 days
8 meters:
63 days
32 meters:
16 days
64 meters:
8 days
128 meters:
4 days

Mobile Network

GPRS class:
Up to 12
Band:
850/900/1800/1900 MHz

Fixed Network (Ethernet)

Integration

Meter implementation:
Landis+Gyr UH50/UC50

Approvals

EMC:
EN 61000-6-2, EN 61000-6-3
Safety:
EN 61010-1, CAT 2

Connections and Interfaces

Transmissions

For downloads, please visit our support site at: https://support.elvaco.com